Xinghe Da Technology Co., Ltd
Contacts:Jack Peng
Mobile:+86 18627553022
Whatsapp:+86 18627553022
WeChat: pengyi-changsha
E-mail:admin@chinaxingheda.com
Company address :2506 Xidi Building, No. 8 Fenglin Third Road, Yuelu District, Changsha City, Hunan Province
OLT,XPON-HUAWEI FMCA Fan Tray Equipment
Product Description
MA5603T Fan Tray(FMCA)
A fan tray functions heat dissipation, monitoring, and fan speed adjustment, which ensures that the device works at a stable temperature
Appearance
Six fans are configured in the fan tray (FMCA) of the MA5603T
Product Details:


Product Description
MA5603T Fan Tray(FMCA)
A fan tray functions heat dissipation, monitoring, and fan speed adjustment, which ensures that the device works at a stable temperature.
Appearance
Six fans are configured in the fan tray (FMCA) of the MA5603T.
Specification
Item | Specification |
Dimensions (W x D x H) | 53.0 mm x 272.5 mm x 245.7 mm |
Weight | 2.0 kg |
Power consumption (including FMCA board) | Static: 30 W Maximum: 72 W |
The functions of the fan tray are as follows:
Heat dissipation
The fan tray is at the left of the service subrack and blows air for heat dissipation of the service subrack. The cool air flows to the subrack from the left of the subrack and then is exhausted from the right of the subrack after passing the boards.
Monitoring
The fan tray is configured with a fan monitoring board. The fan monitoring board transmits speed adjustment signals to the fan tray, collects the rotating speed signals of the fans, and reports the rotating speed signals to the control board.
Speed adjustment
The rotating speed of the fans can be adjusted according to the detected temperature automatically or be adjusted by software manually.
LED
Indicator | Status | Meaning | Operation Description |
STATUS | Yellow: blinks every 0.3s | The fan tray is not registered or is being loaded. | No action is required. |
The communication between the host and the fan tray is interrupted. | Check communication between the fan tray and device. | ||
Green: blinks | The fan tray works in the normal state. | No action is required. | |
Yellow: blinks every 1s | The fan tray generates alarms that do not affect services. | Handle it based on the corresponding alarm. | |
Red: blinks | The fan tray is faulty or the fan tray generates an over-temperature alarm. | Increase the fan speed to lower the temperature. Replace the faulty fan tray. |
DIP Switches
The fan tray uses the FMCA monitoring board, which supports the -48 V / -60 V input voltage, which provides a set of DIP switches S1.
Table 1 describes the settings of S1.
Table 1 Settings of S1
DIP Switch | Indication | Default Settings | |
S1-1 | It is used to set the subnode address of the fan tray that maps the data configuration. ON: The address bit is 0. OFF: The address bit is 1. By default, the address bit is 1. |
OFF | |
S1-2 | ON | ||
S1-3 | ON | ||
S1-4 | ON | The baud rate of the communication between the fan tray and the control board is 19200 bit/s. | ON |
OFF | The baud rate of the communication between the fan tray and the control board is 9600 bit/s. | ||
S1-5 | It is used to set the quantity of fans. | ON | |
S1-6 | ON | ||
S1-7 | It is used to set the mode of adjusting the fan speed. | ON | |
S1-8 | ON |
Table 2 Settings of S1-1, S1-2, and S1-3
S1-3 | S1-2 | S1-1 | Address Value |
ON | ON | ON | 0 |
ON | ON | OFF | 1 |
ON | OFF | ON | 2 |
ON | OFF | OFF | 3 |
OFF | ON | ON | 4 |
OFF | ON | OFF | 5 |
OFF | OFF | ON | 6 |
OFF | OFF | OFF | 7 |
When S1-1, S1-2, and W1-3 are used to set the subnode address, make sure that the DIP switch settings are consistent with the data configuration. But the subnode address value cannot be the same as that of the environment monitoring board.
Table 3 Settings of S1-5 and S1-6
S1-6 | S1-5 | Fan Quantity |
ON | ON | 6 |
ON | OFF | 8 |
OFF | ON | 4 |
OFF | OFF | 10 |
S1-8 | S1-7 | Speed Adjustment Mode | Adjustment Strategy |
ON | ON | Temperature measurement at the air intake vent (reserved) | Strategy 1 |
ON | OFF | Temperature measurement at the air exhaust vent | Strategy 2 |
OFF | ON | Temperature measurement at the air intake vent | Strategy 3 |
OFF | OFF | Temperature measurement at the air intake vent (the fan stops rotating) | Strategy 4 |
NOTE:
The fan tray (FMCA) of the MA5603T must use speed adjustment policy 1.
Fan Speed Adjustment
Set the fan speed adjustment mode to "automatic" or "manual" in the command line interface (CLI). After the fans are installed, they work in automatic mode by default.
Automatic mode
Control-system-triggering: The control system automatically adjusts fan speed according to the board temperatures for energy conservation.
Monitoring-board-triggering: The speed is automatically adjusted based on the temperature which is detected by a temperature sensor.
NOTE:
The automatic mode has two variants (automatically selected by the system): control-system-triggering and monitoring-board-triggering.
Manual mode
Commands are executed to adjust fan speed. The levels range from 0 to 6, level 0 being the lowest speed and level 6 being the highest speed.
A Free Consultation
You can contact us any way that is convenient for you. We are available 24/7 via fax, email or telephone.